2015-3-16 品格继续为某工程公司提供翻译服务。翻译内容:高铁通信系统。翻译方向:中译英。

译文摘录:

3.2.2 BSC单机测试

3.2.2 BSC Single Test

测试目的:
Test Purpose:

验证BSC设备上电完毕后,设备的功能满足合同849要求。使设备在单机测试之后入网联调。
To verify that the function of equipment meets the requirements provided by Contract 849 after BSC equipment is powered up. Connect the equipment to network for joint debugging after single test.

前提条件:
Prerequisites:

单机测试方案中3.1单机测试前设备加电步骤通过。
The step of 3.1 equipment power-on before single test is passed as required in the single test program.

(1) BSC设备上电及单板状态确认
(1) Confirm the State of BSC Equipment Power-on and Single Board

上电步骤:
Power-on Steps:

A:将BSC插框内部所有单板拔出脱离背板插槽,避免插框上电时电流冲击致使单板烧坏;
A: Pull out all the single boards inside the BSC subrack from the backplane slot to avoid single board burned out by the current of subrack power-on;

B:在BSC机柜顶部的配电盒中将插框所对应的空开拨至“ON”,运行5分钟后,观察风扇盒前面板电源指示灯,指示灯为绿色慢闪(1s亮,1s灭)说明插框运行正常,进行C步操作;
B: In the distribution box at the top of BSC cabinet, turn the air switch corresponding to subrack to “ON”; after five minutes of running, observe the power indicator light in the front panel of fan box, and green flash slowly (on and off interval of 1s) indicates the subrack operating normally; C-step can be performed;

C:将A中所拔出的单板插入对应槽位,运行5分钟后观察各个单板RUN运行灯状态,指示灯为绿色慢闪(1s亮,1s灭)说明单板运行正常,进行D步操作;
C: Insert the single board pulled out in A into the corresponding slot; observe the state of running indicator after five minutes of running, and green flash slowly (on and off interval of 1s) indicates it operating normally; D step can be performed;
3.2.5 Repeater Single Test

测试目的:
Test Purpose:

验证直放站设备上电完毕后,设备的功能满足合同849要求。使设备在单机测试之后入网联调。
To verify that the function of equipment meets the requirements provided by Contract 849 after repeater equipment is powered up. Connect the equipment to network for joint debugging after single test.
前提条件:
Prerequisites:
单机测试方案中3.1单机测试前设备加电步骤通过。
The step of 3.1 equipment power-on before single test is passed as required in the single test program.

(1) Comlab直放站
(1)Comlab Repeater

说明:
Explanation:

A: Comlab 直放站MU/RU连接图
A: Comlab Repeater MU / RU Connection Diagram

用测试网线连接笔记本电脑和MU/RU的MOXA(端口LAN1口),对照机箱侧标识牌中设备IP,能Ping通即可。
Connect laptops with MOXA (LAN1 port) of MU / RU by test cable, input the equipment IP on the side nameplate in the chassis till the Ping order takes effect.

B: 调测软件使用简要说明
B: Brief explanation to the commissioning software

在终端电脑上双击软件图标,打开调测软件,点击左上角电脑图标,选择近端或远端,输入设备IP地址登录,如图13所示:
Double-click the software icon on the terminal computer, then the commissioning software will be open, select the proximal or distal end, and enter the equipment IP address to login, as shown in Figure 13: